supports multi-frequency synthesis, Stokes and spectral imaging.
imsize
should be large enough to contain all emission
in the main lobe of the primary beam (as MIRIAD
only models the main
lobe, making it larger has no beneficial effect).
Table 20.2 gives these
sizes as a function of frequency for the ATCA.
Table 20.2: Size of Main Lobe of the Primary Beam for ATCA dishes
sup
gives the sidelobe
suppression region, and is a way of setting uniform, super-uniform and
sub-uniform weights. In mosaic mode, invert
's default is to suppress
the sidelobes in a region the size of each sub-image. However suppressing
sidelobes in an individual sub-images is not the same as suppressing them
in the linear mosaic of the sub-images. This is because
the linear mosaicing process weights down sidelobes
some distance from the pointing centre.
In mosaicing, minimum sidelobes
will be achieved by setting sup equal to about twice the pointing
separation (which should be about the side of the primary beam FWHM).
As always, best point-source sensitivity results by setting sup equal to 0.