fitslogr input_dev out_file startfnum endfnum
input_dev
Tape drive, e.g. "mta1600" or just "mta"
out_file
Name of output file to store information. Information is appended to this
file to allow one to update a previously created file.
startfnum
Tape file to start logging.
endfnum
Tape file to stop logging.
Fitslogr reads FITS headers from successive tape files and compiles certain information into a single line of output for each file. Currently, the information output for each file includes:
Tape file number, IRAF image name, date, time, and the Carrington longitude for each image.
If all of these header parameters are not present, only the ones found will be printed out and garbage will come out for the empty parameters. The date is stored in a header parameter called OBS_DATE, the time is stored as 'seconds since midnight' in OBS_TIME and the Carrington longitude is stored in L_ZERO. To use this script, both the DATAIO package and the VTEL package must be loaded.
1. To log all of the FITS images on a tape mounted on 'mta' and store the information in a file called 'CX052' the command would be:
vt> fitslogr mta CX052 1 999
2. To log just the 40th through 60th files on mtb and see the output on your terminal, the command would be:
vt> fitslogr mtb STDOUT 40 60