Even on the excellent site of Chajnantor the sensitivity of any
broadband bolometer will be limited by the fluctuations of the ambient
thermal background radiation of the telescope and the atmosphere. The
best existing bolometer arrays, MAMBO and SCUBA, already operate close
to that limit. No doubt this limit can be achieved with different
bolometer technologies. For fully efficient pixels, even the
conventional semiconducting bolometers can achieve the background limit.
The attraction of the superconducting bolometers to be used for LABOCA
is in the promise of cryogenic multiplexing and readout via SQUIDs. The
superconducting bolometers will also give a faster response time, but
not necessarily increased sensitivity. LABOCA will not yet use
multiplexing, but will be a necessary first step toward this goal. The
size of LABOCA was chosen to represent a significant step in throughput
beyond the 117-element MAMBO, while still being feasible with parallel
readout.